<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="case-report" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Orthop Case Reports</journal-id>
<journal-title>Journal of Orthopaedic Case Reports</journal-title>
<issn pub-type="ppub">2250-0685</issn>
<issn pub-type="epub">2321-3817</issn>
<publisher>
<publisher-name>Indian Orthopaedic Research Group</publisher-name>
<publisher-loc>India</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">JOCR-12-107</article-id>
<article-id pub-id-type="doi">10.13107/jocr.2022.v12.i10.3388</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Case Report</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Needle Cap External Fixator for Proximal Phalanx Fracture &#x2013; A Case Report</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Jha</surname>
<given-names>Amrit</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
<xref ref-type="corresp" rid="cor1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Dua</surname>
<given-names>Apoorv</given-names>
</name>
<xref ref-type="aff" rid="aff2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gadkari</surname>
<given-names>Alok</given-names>
</name>
<xref ref-type="aff" rid="aff3">3</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Yadav</surname>
<given-names>Amit Kumar</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Goyal</surname>
<given-names>Navneet</given-names>
</name>
<xref ref-type="aff" rid="aff2">2</xref>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label>Department of Orthopaedics, , Wrightington Hospital, Wigan United Kingdom</aff>
<aff id="aff2"><label>2</label>Department of Orthopaedics, Dr. Baba Saheb Ambedkar Hospital, New Delhi, India</aff>
<aff id="aff3"><label>3</label>Department of Orthopaedics, International Training Fellow at Robeert Jones and Agnes Hunt Hospital, United Kingdom</aff>
<author-notes>
<corresp id="cor1">
<bold>Address of Correspondence:</bold> Dr. Amrit Jha, Department of Orthopaedics, Fellowship in FIFA, Wrightington Hospital, Wigan, United Kingdom. E-mail: <email xlink:href="dramritjha@gmail.com">dramritjha@gmail.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<month>10</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="epub">
<month>10</month>
<year>2022</year>
</pub-date>
<volume>12</volume>
<issue>10</issue>
<fpage>107</fpage>
<lpage>109</lpage>
<history>
<date date-type="received"><day>16</day><month>07</month><year>2022</year></date>
<date date-type="rev-recd"><day>05</day><month>08</month><year>2022</year></date>
<date date-type="accepted"><month>03</month><year>2022</year></date>
</history>
<permissions>
<copyright-statement>Copyright: &#x000a9; Indian Orthopaedic Research Group</copyright-statement>
<copyright-year>2022</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc-sa/3.0">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</p>
</license>
</permissions>
<abstract>
<sec id="st1">
<title>Introduction:</title>
<p>Among all the phalanges, most fractured is the proximal phalanx. Frequently encountered complications are malunion, stiffness, and soft-tissue injury which invariably increase the disability. The aim of fracture reduction, therefore, comprises acceptable alignment and the gliding of the flexor and extensor tendons are maintained. Factors affecting management are fracture location, type of fracture, soft-tissue injury, and fracture stability.</p>
</sec>
<sec id="st2">
<title>Case Report:</title>
<p>A 26-year-gentlemen, right hand dominant, a clerk by occupation, came to emergency with right-hand index finger pain, swelling, and unable to move the right index finger treated with debridement, wound wash, and external fixator frame made with K wire and needle cap. Fracture united in 6 weeks with good hand function and the full range of motion of the hand.</p>
</sec>
<sec id="st3">
<title>Conclusion:</title>
<p>Mini fixator for phalanx fracture is a cheap and reasonably effective procedure. A needle cap fixator is a good alternative in difficult situations, it helps in correcting the deformity as well as keeps the joint surface distracted.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Hand injury</kwd>
<kwd>open fracture</kwd>
<kwd>phalanx fracture</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<boxed-text>
<title>Learning Point of the Article:</title>
<p>Needle External fixator for phalanx fracture is a cheap and reasonably effective procedure.</p>
</boxed-text>
<sec id="sec1-1" sec-type="intro">
<title>Introduction</title>
<p>Metacarpals and phalanges are the most common hand fracture about 10&#x0025;. The proximal phalanx of the fingers is most common fracture phalanx [<xref ref-type="bibr" rid="ref1">1</xref>]. The deformity and displacement are typical when the proximal phalanx fracture involves the outer rays. Proximal phalanx fracture are usually stable and can be treated nonoperatively. The indication of surgery is angulation more than 20 in coronal view and &#x003E;15&#x00B0; in sagittal view, &#x003C;50&#x0025; bone contact, rotational deformity, and collapse [<xref ref-type="bibr" rid="ref2">2</xref>]. Proximal fragment is flexed due to interosseous muscle and lead to apex volar deformity [<xref ref-type="bibr" rid="ref3">3</xref>]. Longitudinal compression force is given by flexor and extensor tendon that shortens the phalanx and distal fragment is extended.</p>
<p>Close non-displaced and minimal displaced proximal phalanx fractures is managed nonoperatively. The goal of surgical treatment is to create a stable construct capable of withstanding gentle forces that are associated with an early range of motion. They include K wire, K wire and fixator, screw fixation, and anatomical plates.</p>
</sec>
<sec id="sec1-2" sec-type="cases">
<title>Case Report</title>
<p>26-year-old gentlemen, right-hand dominant, a clerk by occupation, came to emergency with right-hand index finger pain, swelling, and unable to move the right index finger.</p>
<p>On examination, there was swelling, tenderness, and an open wound over the dorsal aspect of the right hand&#x2019;s second proximal phalanx. The extensor indices tendon was intact on clinical examination. All other systemic examination was normal.</p>
<p>Plain radiograph right hand anteroposterior and oblique show a displaced extra-articular second proximal phalanx fracture (<xref ref-type="fig" rid="F1">Fig. 1</xref>).</p>
<fig id="F1">
<label>Figure 1</label>
<caption>
<p>Plain radiograph right hand anteroposterior and oblique shows a displaced extra-articular second proximal phalanx fracture.</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g001.tif"/>
</fig>
<p>We discussed with the patient regarding surgery and rehabilitation. Written informed consent was taken for surgery. The patient was planned for a universal min external fixator. The patient was operated on under a local ring block with 2&#x0025; of lignocaine without adrenaline. Unfortunately, due to miscommunication between operation theater staff, implant (fixator) was not available for surgery and the team was not aware of this. In this difficult situation, we thought of only debridement for now and postpone the fixation for the next theater list. We proceed with the debridement, extensor indices tendon was intact after the debridement fracture was unstable in length so at that moment, we thought of fixation. 1.2 mm diameter K wire one was passed parallel to the joint proximal to fracture and the second K wire was distal to fracture. The acceptable reduction was achieved in all planes and a sterile needle cap was pierced through one edge only, to avoid injury from exposed ends of K wires (<xref ref-type="fig" rid="F2">Fig. 2</xref>) which act as mini fixator. A wound wash was given and the open wound was closed with ethilon 3&#x2013;0 suture.</p>
<fig id="F2">
<label>Figure 2</label>
<caption>
<p>Clinical picture showing the K wire with needle cap frame.</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g002.tif"/>
</fig>
<p>The finger was immobilized for 2 weeks because we are concerned with the stability of fixation. The patient returned to work the very next day after surgery but advise to avoid heavy work. The patient was reviewed on 14 days for suture removal and finger motion was started to prevent stiffness with a needle cap fixator in situ. On 4-week follow-up, K wire is removed, and a plain radiograph was done. The patient was advised of active finger movement and further follow-up. Plain radiograph at six showing complete fracture union (<xref ref-type="fig" rid="F3">Fig. 3</xref>). We measure grip strength and pinch with a dynamometer which is 90 of normal strength to the opposite limb. The patient has a PIP range of flexion of around 85&#x00B0;.</p>
<fig id="F3">
<label>Figure 3</label>
<caption>
<p>Plain radiograph at six showing complete fracture union.</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g003.tif"/>
</fig>
</sec>
<sec id="sec1-3" sec-type="discussion">
<title>Discussion</title>
<p>Proximal phalanx extra-articular fractures are common and are associated with significant soft-tissue injury. For stable fracture, conservative treatment is the main treatment. The main objective of treatment is union and preserve the gliding mechanism of tendon with normal motion. In lateral view, fracture has palmar apical configuration with distal fragment that is extended due to the short excursion of the extensor tendon hood and lateral bands and proximal fracture is flexed because the intrinsic muscles flex the MCP joint. The treatment options include conservative open reduction internal fixation (ORIF), and external fixators. ORIF can cause impairment of the gliding layers due to soft-tissue damage. Hence, external fixator proves to be a better alternative. It not only reduces further soft-tissue damage but allows mobilization of joints that helps to reduce chances of joint stiffness [<xref ref-type="bibr" rid="ref4">4</xref>].</p>
<p>Suzuki et al. in 1994 described a frame made up of K wire and rubber band for managing intra-articular fracture in hand with good results known widely as the Suzuki frame [<xref ref-type="bibr" rid="ref5">5</xref>].</p>
<p>Badia et al. described an external fixator frame without a rubber band made up of two K wires through the proximal phalanx and head of the middle phalanx for proximal phalanx fracture-dislocation. They achieved good results except in one case where residual pain with flexion [<xref ref-type="bibr" rid="ref6">6</xref>].</p>
<p>Finsen V modified Suzuki frame rubber with vessel loop for fracture of base of middle phalanx and found stiffness in some cases. The reason for stiffness is the thickness of vessel loop and prolonged frame time [<xref ref-type="bibr" rid="ref7">7</xref>]. Inanami et al. used three K wire-made dynamic external fixators for four acute and three malunited fracture dislocation of the proximal phalanx with an average range of 88&#x00B0; [<xref ref-type="bibr" rid="ref8">8</xref>]. Kapur et al. used K wire and jurgan pin balls to construct a frame and treated intra-articular fracture of the middle and proximal phalanx with good results [<xref ref-type="bibr" rid="ref9">9</xref>].</p>
<p>Sastravaha et al. described a Sriracha external fixator frame made by cutting a plastic syringe and passing K wire through the bone and syringe-like quadruple cortical purchase for the treatment of proximal phalanx fracture-dislocation. They found good results equal to other fixator in their study. The advantage of this fixator is the low cost and simplicity of the application [<xref ref-type="bibr" rid="ref10">10</xref>].</p>
</sec>
<sec id="sec1-4" sec-type="conclusion">
<title>Conclusion</title>
<p>Min external fixator for phalanx fracture is a cheap and reasonably effective procedure. A needle cap fixator is a good alternative in difficult situations, it helps in correcting the deformity as well as keeps the joint surface distracted.</p>
<boxed-text>
<title>Clinical Message</title>
<p>A needle cap fixator is a good alternative in a difficult situation, it helps in correcting the deformity as well as keeps the joint surface distracted.</p>
</boxed-text>
</sec>
</body>
<back>
<bio>
<p><inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g004.tif"/></p>
<p><inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g005.tif"/></p>
<p><inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g006.tif"/></p>
<p><inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g007.tif"/></p>
<p><inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="JOCR-12-107-g008.tif"/></p>
</bio>
<ref-list>
<ref id="ref1">
<label>1</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barton</surname>
<given-names>N</given-names>
</name>
</person-group>
<article-title>Internal fixation of hand fractures</article-title>
<source>J Hand Surg Br</source>
<year>1989</year>
<volume>14</volume>
<fpage>139</fpage>
<lpage>42</lpage>
</nlm-citation>
</ref>
<ref id="ref2">
<label>2</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Singh</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Jain</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Mruthyunjaya</surname>
<given-names></given-names>
</name>
<name>
<surname>Ravishankar</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Outcome of closed proximal phalangeal fractures of the hand</article-title>
<source>Indian J Orthop</source>
<year>2011</year>
<volume>45</volume>
<fpage>432</fpage>
<lpage>8</lpage>
</nlm-citation>
</ref>
<ref id="ref3">
<label>3</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kurzen</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Fusetti</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Bonaccio</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Nagy</surname>
<given-names>L</given-names>
</name>
</person-group>
<article-title>Complications after plate fixation of phalangeal fractures</article-title>
<source>J Trauma</source>
<year>2006</year>
<volume>60</volume>
<fpage>841</fpage>
<lpage>3</lpage>
</nlm-citation>
</ref>
<ref id="ref4">
<label>4</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pennig</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Gausepohl</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Mader</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Wulke</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>The use of minimally invasive fixation in fractures of the hand--the minifixator concept</article-title>
<source>Injury</source>
<year>2000</year>
<volume>31</volume>
<issue>Suppl 1</issue>
<fpage>102</fpage>
<lpage>12</lpage>
</nlm-citation>
</ref>
<ref id="ref5">
<label>5</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Suzuki</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Matsunaga</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Sato</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Yokoi</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>The pins and rubbers traction system for treatment of comminuted intraarticular fractures and fracture-dislocations in the hand</article-title>
<source>J Hand Surg Br</source>
<year>1994</year>
<volume>19</volume>
<fpage>98</fpage>
<lpage>107</lpage>
<comment>Erratum in:J Hand Surg [Br] 1994; 19:408</comment>
</nlm-citation>
</ref>
<ref id="ref6">
<label>6</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Badia</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Riano</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Ravikoff</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Khouri</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Gonzalez-Hernandez</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Orbay</surname>
<given-names>JL</given-names>
</name>
</person-group>
<article-title>Dynamic interdigital external fixation for proximal interphalangeal joint fracture dislocations</article-title>
<source>J Hand Surg Am</source>
<year>2005</year>
<volume>30</volume>
<fpage>154</fpage>
<lpage>60</lpage>
</nlm-citation>
</ref>
<ref id="ref7">
<label>7</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Finsen</surname>
<given-names>V</given-names>
</name>
</person-group>
<article-title>Suzuki&#x0027;s pins and rubber traction for fractures of the base of the middle phalanx</article-title>
<source>J Plast Surg Hand Surg</source>
<year>2010</year>
<volume>44</volume>
<fpage>209</fpage>
<lpage>13</lpage>
</nlm-citation>
</ref>
<ref id="ref8">
<label>8</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Inanami</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Ninomiya</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Okutsu</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Tarui</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>Dynamic external finger fixator for fracture dislocation of the proximal interphalangeal joint</article-title>
<source>J Hand Surg Am</source>
<year>1993</year>
<volume>18</volume>
<fpage>160</fpage>
<lpage>4</lpage>
</nlm-citation>
</ref>
<ref id="ref9">
<label>9</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kapur</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Paniker</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Casaletto</surname>
<given-names>J</given-names>
</name>
</person-group>
<article-title>An alternative technique for external fixation of traumatic intra-articular fractures of proximal and middle phalanx</article-title>
<source>Tech Hand Up Extrem Surg</source>
<year>2015</year>
<volume>19</volume>
<fpage>163</fpage>
<lpage>7</lpage>
</nlm-citation>
</ref>
<ref id="ref10">
<label>10</label>
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sastravaha</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Limudomporn</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Taweewuthisub</surname>
<given-names>W</given-names>
</name>
</person-group>
<article-title>A novel technique for dynamic external fixation of proximal interphalangeal joint fracture-dislocations</article-title>
<source>J Hand Surg Asian Pac Vol</source>
<year>2020</year>
<volume>25</volume>
<fpage>427</fpage>
<lpage>33</lpage>
</nlm-citation>
</ref>
</ref-list>
<fn-group>
<fn fn-type="conflict">
<p><bold>Conflict of Interest:</bold> Nil</p>
</fn>
<fn fn-type="supported-by">
<p><bold>Source of Support:</bold> Nil</p>
</fn>
<fn fn-type="other">
<p><bold>Consent:</bold> The authors confirm that informed consent was obtained from the patient for publication of this case report</p>
</fn>
</fn-group>
</back>
</article>
